Vascular Biology |
From the Departments of Internal Medicine I (T.S., K.S., M.O., M. Shiigai, F.O.) and Surgery II (M. Shimizu, T.M.), National Defense Medical College, Saitama, Japan.
Correspondence to Tadashi Shinohara, MD, Internal Medicine I, National Defense Medical College, 3-2 Namiki, Tokorozawa, Saitama 359-8513, Japan. E-mail kogen{at}me.ndmc.ac.jp
Objective We aimed to establish an enzyme-linked immunosorbent assay for measuring soluble elastin fragments (sELAF) in serum and to reveal its usefulness in diagnosing acute aortic dissection (AAD).
Methods and Results An enzyme-linked immunosorbent assay to measure sELAF in serum was developed by using the newly created double monoclonal antibodies, which recognize the different epitopes of human aortic elastin. Twenty-five AAD patients, 50 patients with acute myocardial infarction (AMI), and 474 healthy individuals were enrolled in the study. The sELAF levels from healthy subjects gradually increased with aging. When the cutoff point for positivity was set at the mean+3 SD (ie, 3 SD above the mean in healthy subjects at each age), 16 AAD patients (64.0%) were found be positive, whereas only 1 AMI patient was found to be positive (2.0%). AAD patients with either an open or a partially open pseudolumen were found be 88.9% positive for sELAF, whereas those with its early closure were 0% positive. The difference in the sELAF levels between AAD patients with and without a thrombotic closure of false lumen was significant (60.3±15.6 versus 135.4±53.2 ng/mL, respectively; P<0.005).
Conclusions The sELAF level in serum may be a useful marker for helping in the diagnosis and screening of AAD and may also help to distinguish AAD from AMI.
Key Words: matrix protein elastin degradation aortic media intimal tear false lumen
This article has been cited by other articles:
![]() |
P. D. Patel and R. R. Arora Pathophysiology, diagnosis, and management of aortic dissection Therapeutic Advances in Cardiovascular Disease, December 1, 2008; 2(6): 439 - 468. [Abstract] [PDF] |
||||
![]() |
H. Ince and C. A Nienaber Diagnosis and management of patients with aortic dissection Heart, February 1, 2007; 93(2): 266 - 270. [Full Text] [PDF] |
||||
![]() |
T Weber, M Rammer, J Auer, E Maurer, G Aspock, and B Eber Plasma concentrations of D-dimer predict mortality in acute type A aortic dissection. Heart, June 1, 2006; 92(6): 836 - 837. [Full Text] [PDF] |
||||
![]() |
T. T. Tsai, C. A. Nienaber, and K. A. Eagle Acute Aortic Syndromes Circulation, December 13, 2005; 112(24): 3802 - 3813. [Full Text] [PDF] |
||||
![]() |
A. Robinet, A. Fahem, J.-H. Cauchard, E. Huet, L. Vincent, S. Lorimier, F. Antonicelli, C. Soria, M. Crepin, W. Hornebeck, et al. Elastin-derived peptides enhance angiogenesis by promoting endothelial cell migration and tubulogenesis through upregulation of MT1-MMP J. Cell Sci., January 15, 2005; 118(2): 343 - 356. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Eggebrecht, C. K. Naber, C. Bruch, K. Kroger, C. von Birgelen, A. Schmermund, M. Wichert, T. Bartel, K. Mann, and R. Erbel Value of plasma fibrin D-dimers for detection of acute aortic dissection J. Am. Coll. Cardiol., August 18, 2004; 44(4): 804 - 809. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. W. Olin and V. Fuster Acute Aortic Dissection: The Need for Rapid, Accurate, and Readily Available Diagnostic Strategies Arterioscler Thromb Vasc Biol, October 1, 2003; 23(10): 1721 - 1723. [Full Text] [PDF] |
||||
|
ATVB Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2003 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |