| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Vascular Biology |
From the Department of Cardiovascular Medicine (Z.A.A., N.J.A., T.B., S.M., K.M.C.), University of Oxford, John Radcliffe Hospital, UK; Brivant Ltd (H.L., J.G.), Oranmore, Galway, Ireland; the Cardiovascular Research Group (N.A., M.W.), University of Sheffield, Northern General Hospital, UK; Sir William Dunn School of Pathology (D.R.G.), University of Oxford, UK; and the Cardiovascular Division (Y.H.), Kings College, London, UK.
Correspondence to Professor Keith Channon, Department of Cardiovascular Medicine, University of Oxford, John Radcliffe Hospital, Oxford, OX3 9DU, UK. E-mail keith.channon{at}cardiov.ox.ac.uk
| Abstract |
|---|
|
|
|---|
Methods and Results Aortic segments from either C57BL/6 wild-type or atherosclerotic ApoE-KO mice underwent balloon angioplasty alone or balloon angioplasty and stenting with a 1.25x2.5 mm stainless steel stent. Vessels were carotid-interposition grafted into genetically identical littermate recipients and harvested at 1, 7, 14, or 28 days. In wild-type mice, stenting generated an inflammatory vascular injury response between days 1 to 7, leading to the development of neointimal hyperplasia by day 14, which further increased in area by day 28 leading to the development of in-stent stenosis. Uninjured vessels and vessels injured by balloon angioplasty alone developed minimal neointimal hyperplasia. In stented ApoE-KO mice, neointimal area at 28 days was 30% greater compared with wild-type mice.
Conclusions By reproducing important features of human stenting in atherosclerotic mice, we provide the potential to investigate molecular pathways and evaluate novel therapeutic targets for stent injury and restenosis.
In this study we describe the first mouse model of balloon angioplasty and stenting. This new model reproduces features of human percutaneous coronary intervention and provides the potential to investigate molecular pathways and evaluate novel therapeutic targets for stent injury and restenosis.
Key Words: vascular biology genetically modified mice angioplasty stents restenosis
| Introduction |
|---|
|
|
|---|
See page 701
Various experimental models have been used in the preclinical development of stenting, including rabbit, rat, and pig models.4 Although these systems reproduce some aspects of the human vascular response to PCI, there are limitations in replicating the typical features of human atherosclerosis. In addition, constraints in genetic manipulation limit existing large-animal models to pharmacological and physical interventions, rather than dissection of relevant biological pathways by genomic approaches. In contrast, genetically-modified mice have provided important insights into the role of specific pathways in the pathophysiology of atherosclerosis and other vascular disease states.5 Mouse models also provide refinements in laboratory animal use, are cost-effective, and have a favorable generation time for cross-breeding experiments. Although mouse models would provide powerful approaches to investigate molecular mechanisms relevant to angioplasty and stenting, technical challenges have restricted such studies in mice to surrogate models of vascular injury, such as wire-denudation of endothelium6,7 or perivascular polyethylene cuff placement.8 These models have significant limitations in their ability to address potentially important aspects of balloon angioplasty and stenting.
Accordingly, we aimed to develop a mouse model of balloon angioplasty and stenting that would reproduce important mechanical aspects of clinical PCI, enable studies in genetically modified mice relevant to atherosclerosis, and allow studies of both local and systemic aspects of the vascular response to stent injury.
Developing a mouse model of arterial stenting poses unique challenges. The small animal size leads to technical difficulties in stent design, deployment techniques, and availability of suitable target vessels. Furthermore, the importance of stent geometry in the response to stent injury in humans9 requires careful stent bioengineering to replicate these properties in mice. Based on a series of preliminary designs and stent deployment studies, we developed a 2.5 mm-length stainless steel slotted tube stent to generate medial angulation and stretch, inter-strut distance, and strut surface area in mouse aorta analogous to human coronary stenting. We deployed the stent in thoracic aortas of donor mice using a clinical 1.25 mm-diameter balloon angioplasty catheter, after which the stented segment was explanted and grafted into the arterial circulation of littermate recipient mice. We evaluated the vascular injury responses to both balloon angioplasty and stenting in C57BL/6 (wild-type) mice, and then compared these with the responses in the genetically modified atherosclerotic apolipoprotein E-knockout (ApoE-KO) mouse model of atherosclerosis.1012
| Methods |
|---|
|
|
|---|
Arterial Stent-Graft Procedure
All animal procedures were carried out in accordance with the UK Home Office Animals (Scientific Procedures) Act 1986. All operative procedures involved grafting a thoracic aortic segment from a female donor mouse to the carotid artery of a male littermate recipient, of identical genotype. One week before operation, mice received aspirin 10 mg/kg/d in drinking water, and this was continued throughout the experimental period. Mice were anesthetized using a combination of subcutaneous Hypnorm (25 mg/kg, Bayer) and Hypnoval (25 mg/kg, Roche).
In the donor (female) mouse, the anterior thoracic cage was reflected superiorly. Heparinized phosphate buffered saline solution (PBS) (0.5 mL, (100 iU/mL) was injected via cardiac puncture of the left ventricle after which the thoracic aorta was isolated from arch to diaphragm. Periaortic fat was carefully dissected off. The right atrium was then opened as a vent and a further 5 ml of heparinized saline injected as flush. A small transverse arteriotomy was made just superior to the diaphragmatic outlet. A stainless-steel stent (Brivant Ltd), 2.5x0.6 mm in dimension (supplemental Figure I, available online at http://atvb.ahajournals.org), was crimped onto a 1.25x13 mm balloon angioplasty catheter (Avion Plus, Invatec International) and guided retrograde up the thoracic aorta. The catheter was advanced so that the stent was placed in the mid portion of the descending thoracic aorta and the balloon inflated to 8 atmospheres pressure for 30 seconds deploying the stent to a final internal diameter of 1.25 mm (balloon-to-vessel ratio of 1.5:1). The balloon catheter was removed, leaving the deployed stent in situ, and the stented aorta harvested by sealing the intercostal branch vessels with electrocautery. The stented aortas were washed and stored in heparinized PBS, maintaining an ischemic time of 15 minutes for all vessels (whether un-injured aorta, balloon-injured aorta, or stented aorta).
In the recipient (male) mouse, the right common carotid artery was isolated and mobilized from the thoracic inlet to its bifurcation, ligated, and divided between ties at its midpoint. Polyethylene cuffs (0.65 mm diameter, Portex Ltd) were placed over the ends and anchored by microhemostatic clamps (Aesculap). Sutures at the ends of the artery were removed, and the artery everted over the cuffs and secured with 8-0 silk sutures. The stented aorta from the donor mouse was interposition grafted by sleeving the ends of the aorta over the 2 ends of the carotid artery and ligating them with 8-0 silk sutures. Vigorous pulsation in the conduit vessel confirmed successful engraftment. The skin was closed using a continuous 5/0 suture. The median total procedure time was approximately 60 minutes. The operative procedure is summarized in Figure 1A.
|
Tissue Preparation, Histology, and Lesion Quantification
Vessels were harvested 28 days after surgery and perfusion fixed in situ with 4% phosphate-buffered paraformaldehyde. Vessels were excised, fixed in paraformaldehyde overnight, and subsequently embedded into glycol methacrylate resin (Technovit 8100, TAAB Laboratories) for histomorphometry, or methyl methacrylate resin (Technovit 9100, TAAB Laboratories) for immunohistochemistry, according to the manufacturers instructions. Four transverse sections were cut through each stent using an Isomet 5000 diamond-coated rotary saw and polished (to 5 to 10 µm) using a Metaserv 2000 polisher (Buehler).
For histomorphometric analysis, sections were stained with hematoxylin and eosin. Lesions were quantified for total vessel area (area inside the external elastic lamina), neointimal area (area inside the internal elastic lamina, minus stent struts, minus lumen), lumen, and stent expansion (area inside a polygon connecting the midpoint of each stent strut). In some vessels, measurements of neointimal thickness were performed by measuring the perpendicular distance from lumen to internal elastic lamina at the mid point between stent struts on each section (4 to 6 measurements per section; 4 sections per vessel to generate n=1).
Immunohistochemistry
Immunohistochemistry was performed by dissolving the methyl methacrylate resin according to the manufacturers instructions. Vessel sections were stained for platelets (adsorbed rabbit anti-mouse thrombocyte, 1:20 000, Clone 1A4, Inter-Cell Technologies), macrophage/monocytes (monoclonal rat anti-mouse macrophage/monocytes MAC-3, 1:50, Clone M3/84, Pharmingen), proliferating cells (monoclonal rat anti-mouse Ki67, Clone TEC-1), and SMC
-actin (alkaline-phosphatase conjugated monoclonal anti-
-smooth muscle actin, 1:50, Clone 1A4, Sigma).
Image analysis was performed using Image Pro Plus software (Media Cybernetics). Vessel cell density and surface-adherent leukocytes were measured at x200 light magnification by manual cell counting. For quantification of immunohistochemistry (platelets, macrophages, cell proliferation, SMCs, and collagen), the total stained area was determined by computerized threshold segmentation of colors. Using this technique, stained area is isolated according to a standardized color threshold set based on staining in appropriate positive controls. Positive staining is presented as a percentage of the total neointima. Four sections spanning the entire length of the vessel were combined as n=1 for all quantifications. All histological analysis was performed in a blinded fashion.
Injury and Inflammation Scores
Arterial injury and inflammation after stenting was determined by the anatomic structures penetrated by each stent strut using two previously described methods. For the Schwartz13 injury score a numeric value was assigned to each stent strut in every section as follows: 0=no injury, 1=perforation in internal elastic lamina, 2=medial perforation, 3=perforation in external elastic lamina. For inflammation score14 a numeric value was assigned to each stent strut as follows: 0=no inflammatory cells surrounding the strut; 1=light, noncircumferential lymphohistocytic infiltrate surrounding the strut; 2=localized, moderate to dense cellular aggregate surrounding the strut noncircumferentially; and 3=circumferential dense lymphohistiocytic cell infiltration of the strut.
Optical Coherence Tomography
Optical coherence tomography (OCT) is an imaging technique able to capture high resolution cross-sectional images in real time. OCT images were acquired using an Imagewire (TM) (Lightlab Imaging Inc) at 8.2 frames per second with a center wavelength of 1310 nm and a bandwidth of 70 nm, providing an axial resolution of approximately 10 µm and a transverse resolution of approximately 25 µm. Imaging of stented vessels was performed ex vivo. Before imaging, the stented vessel was placed into a Petri dish and immersed in PBS. Under the light microscope, the stented vessel was cannulated and the imaging catheter carefully advanced beyond the stented segment. The vessel was then imaged by automated pullback at 0.5 mm/second. For 3D reconstruction of the whole vascular segment, individual cross-sectional images from a stented vessel harvested 14 days postoperatively were converted to 2D TIFF files, and segmented into vascular regions of interest: (carotid-cuff-aorta, stented media, stent struts, stented intima, aortic media, aortic intima, and carotid artery) using masking software in Adobe Photoshop-CS. The individual segmented TIFF images were then stacked using Image Pro 3D Suite (Media Cybernetics) to produce a 3D reconstruction of the stented vessel.
Lipid and Lipoprotein Analysis
Total plasma cholesterol and triglyceride concentrations were measured using enzymatic assay (Roche) on a Cobas Mira Plus automated analyzer (Roche).
Statistical Analysis
Data are presented as mean±SEM. Data were subjected to the Kolmogorov-Smirnov test to determine distribution. Groups were compared using the Mann-Whitney U test for nonparametric data or the Student t test for parametric data. When comparing multiple groups data were analyzed by analysis of variance with Bonferroni post test for multiple testing for parametric data. A value of P<0.05 was considered statistically significant.
| Results |
|---|
|
|
|---|
To demonstrate the morphological changes from carotid artery, via cuff, to aortic stent graft we performed OCT imaging of paraformaldehyde fixed stented vessels ex vivo. A 3D reconstruction of a stented aorta harvested 14 days post-operatively is shown in Figure 1B. The luminal area of the stented aorta measured approximately 5-fold higher (0.57±0.04 mm2), and the unstented aorta 3-fold higher (0.35±0.02 mm2), than the carotid artery (0.11±0.05 mm2).
Time Course of the Response to Balloon Angioplasty and Stenting in C57BL/6 Mice
To determine the biological response in mouse vessels to stenting, we performed a systematic time-course evaluation of histomorphometry at 1, 7, 14, and 28 days post-implantation in wild-type C57BL/6 mice.
Histomorphometry
One day after the stenting procedure, balloon deployment provided symmetrical stent expansion and uniform stretching of the vessel media around the stent struts (Figure 2). Stent expansion increased the total vessel wall area by approximately 50% compared with reference aorta. Neointimal hyperplasia increased progressively over the 28 day time period as evidenced by measures of both neointimal thickness and neointimal area (P<0.0001) (Figure 2 and Table 1). Neointimal thickness also increased during the 28 day period, following a similar pattern to the measurements of neointimal area (Table 1). Because total medial area remained consistent through the 4 time points, a progressive increase in the neointima to media ratio over time was also observed (P<0.0001) (Table 1). Consistent with these findings, luminal area significantly decreased between day 1 and day 28 (P<0.02), equating to in-stent stenosis of 1.3±0.2, 10.8±1.5, 15.6±1.4, and 32.9±2.0% on days 1, 3, 7, and 28 respectively (P<0.0001) (Table 1). Importantly, stent expansion was not different between the various time points, indicating that in-stent stenosis was the result of neointimal hyperplasia (Table 1). Furthermore, injury scores were not different among the time intervals (Table 1).
|
|
Histology
Histological analyses of stented vessels harvested at the 4 time points are shown in Figure 3 and Table 2. One day after stent implantation, the luminal surface of the stented vessel was covered with a monolayer of leukocytes (Figure 3A and Table 2), and a thin adherent monolayer which stained positively with a monoclonal antibody against mouse platelets (Figure 3C and Table 2). Staining for proliferating cells identified small clusters of cells within the media. Monocyte/ macrophage staining was negative. By 7 days, mural thrombi surrounded the stent struts (Figure 2 and Table 2). Leukocytes (Figure 3B) and platelets (Figure 3D) were present on the injured surface and lined the organizing thrombus/neointima, which also contained some macrophages (Figure 3E) and a high proportion of proliferating cells (Figure 3G and Table 2). At 14 days, the localized thrombus was no longer present, and a defined neointima (Figure 2), which stained positively for SMC
-actin (Figure 3I), was seen. Masson trichrome staining revealed that a proportion of the neointima was composed of collagen and elastin (Figure 3K and Table 2). Monocyte/macrophage staining increased and was predominant in the peri-strut regions (Figure 3F and Table 2). Furthermore, the total number of proliferating cells at 14 days was similar to 7 days, yet as a proportion of the neointima markedly decreased (Table 2). Platelet staining was absent. Twenty-eight days after the procedure a marked neointima was present, leading to moderate in-stent stenosis (Figure 2). The proportion of the neointima which stained positive with
-actin increased (Figure 3J and Table 2), as did the collagen and elastin content of the neointima (Figure 3L and Table 2). Monocyte/macrophage and cell proliferation staining both decreased compared with 7 and 14 days.
|
|
Comparison of Balloon Angioplasty and Stenting in C57BL/6 and ApoE-KO Mice
We next sought to determine how the vascular response to stent injury differed in genetically modified ApoE-KO mice compared with C57BL/6 mice, and aimed to establish the statistical power of this model for comparing the neointimal hyperplasia response at 28 days between mouse strains.
Cholesterol levels in ApoE-KO mice were significantly higher compared with wild-type mice (431±23 mg/dL versus 51±4 mg/dL; P<0.001) (supplemental Table I). To confirm that ApoE-KO mice developed the expected vascular phenotype of atherosclerosis, we evaluated histological sections of aortas using the Masson-Goldner stain. Aortas from 22-week-old ApoE-KO mice indeed demonstrated lipid deposition and typical atherosclerotic lesions, which were not observed in wild-type mice of the same age (supplemental Figure II).
Histomorphometry
Twenty-eight days after operation, uninjured arterial grafts in both wild-type mice and ApoE-KO mice had appearances similar to control noninstrumented mouse aorta (Figure 4A), indicating that the surgical procedure itself did not induce a significant vascular injury response. Despite acute stretching of the vessel wall during inflation, balloon angioplasty did not increase total vessel wall area at 28 days in either genotype compared with uninjured controls. However, balloon angioplasty resulted in neointimal hyperplasia that was 3-fold (P<0.01) greater in ApoE-KO mice compared with wild-type mice (Figure 4A). In ApoE-KO mice, neointimal hyperplasia caused significant luminal narrowing compared with both wild-type balloon-injured and uninjured control vessels (Figure 4A and 4B).
|
Stenting significantly increased neointimal hyperplasia compared with balloon angioplasty alone (Figure 4A and 4B). In atherosclerotic ApoE-KO mice neointimal hyperplasia in stented vessels was further increased by 30%, compared with wild-type animals. Stenting also increased total vessel area by >50% compared with balloon angioplasty (equivalent to a vessel diameter expansion ratio of 1.2:1), resulting in an overall increase in lumen area in stented vessels. However, lumen area was significantly reduced in ApoE-KO mice compared with wild-type mice (Figure 4A and 4B).
Based on the mean and standard deviation of the neointimal area measurements at 28 days in ApoE-KO mice, a power calculation (using 2-tailed statistical testing) indicated that this model would be able to distinguish a relative neointimal area difference of 20% using 8 mice per group, assuming a conventional alpha value of 0.05 and a statistical power of 80%.
Stent Injury and Inflammation Scores
The extent of vascular injury13 and inflammation14 caused by stent deployment is an important determinant of neointimal hyperplasia. Because our stent was deployed using an identical angioplasty balloon inflated to a consistent pressure in all animals, there were no differences between wild-type and ApoE-KO stented vessels in either stent expansion (0.80±0.02 versus 0.86±.08 mm2, P=0.47) or mean Schwartz vessel injury score13 (1.3±0.3 versus 1.4±0.4; P=0.54). Despite this, inflammation scores14 were significantly higher in ApoE-KO stented vessels (2.1+0.1 versus 1.0±0.2; P<0.001) compared with wild-type vessels.
Immunohistochemistry
Immunohistochemical analysis of the cellular composition of the neointima of stented vessels revealed smooth muscle cells and macrophages, identified by
-actin and MAC-3 immunostaining, respectively. Importantly, we observed a significant increase in both the absolute and relative content of MAC-3positive macrophages within the neointima of stented ApoE-KO vessels compared with stented wild-type vessels (supplemental Figure III). Absolute levels of
-actin-positive cells were higher in stented ApoE-KO vessels in keeping with increased neointimal hyperplasia. However, there was no difference in the proportion of smooth muscle cells to vessel area between groups.
| Discussion |
|---|
|
|
|---|
The ideal model of in-stent stenosis should use animals that are inexpensive, readily available, convenient to breed, and that develop lesions over relatively short time periods. We have developed and validated a model which fulfils these criteria but also provides the advantage of investigating the role of key genes through transgenic and knockout technology. Importantly, the time course of neointimal hyperplasia in the present study is similar to that found in rat,1517 rabbit,1820 and pig models.13,2123 In the present study, 1 day after stenting the luminal surface showed a predominance of surface-adherent leukocytes and platelets. By 7 days highly proliferative granulation tissue containing organizing thrombus, inflammatory cells, and SMCs extended between the stent struts. At 14 days there was a mature neointima containing collagen, elastin, and SMCs, with a predominance of macrophages around the stent struts. Finally, by 28 days cellular proliferation was markedly reduced, and a mature neointima predominantly comprising SMCs and connective tissue with some macrophages resulted in moderate in-stent stenosis.
In clinical practice, deployment of a stent reduces restenosis compared with balloon angioplasty alone,24,25 and endovascular stenting is now the most commonly performed technique for coronary revascularization. Stent deployment creates a persistent scaffold in the vessel wall, leading to greater acute gain in lumen diameter, so that subsequent neointimal hyperplasia less often results in clinically important restenosis. However, the greater vessel stretch and injury generated by stenting may paradoxically result in more vigorous neointimal hyperplasia.13,26 In our model stented animals developed reproducible in-stent stenosis, with significantly greater neointimal area compared with balloon angioplasty. Despite increased neointima in the stented animals, lumen area was maintained. In ApoE-KO vessels neointimal area was 30% greater compared with wild-type. Furthermore, balloon angioplasty in ApoE-KO mice resulted in a 60% reduction in lumen area analogous to the constrictive remodelling and restenosis seen following balloon angioplasty in diseased human coronary arteries.24,25
Inflammation may play a pivotal role linking vascular injury to in-stent restenosis, because increased vascular monocyte content is associated with increased neointimal hyperplasia in both animal models and in humans.2729 In mouse models, targeted deletion of the ApoE gene leads to spontaneous atherosclerosis and increased vascular inflammation.1012 In our model, despite no differences in stent expansion or injury score, inflammation and monocyte/macrophage concentration was significantly higher in ApoE-KO stented vessels compared with wild-type. These results indicate that differences in neointimal hyperplasia and inflammation after stenting were related to genotype rather than mechanical factors. These findings, together with the similarities in cellular composition of the neointima in mouse and human,30,31 further validates the clinical relevance of balloon angioplasty and stenting in mice.
In our model, the stent is deployed in the aorta of a donor mouse then grafted into a recipient. This strategy is technically more straightforward than attempting to deploy a stent in situ during recovery anesthesia. Furthermore, grafting a stented vessel from a mouse of one genotype into a mouse of another genotype provides a valuable approach to investigate local versus systemic aspects of the vascular response to stent injury independently, using appropriate crossover experimental designs. This would allow investigation, for example, of the role of endothelial or smooth muscle cell repopulation in the development of neointimal hyperplasia following stenting.
Our findings indicate that hypercholesterolemia, and increased vascular inflammation in the ApoE-KO mouse is associated with increased in-stent stenosis. However, our model is not limited to studies of atherosclerosis, because we observed substantial neointimal hyperplasia after stenting even in wild-type C57BL/6 mice. This finding has important implications for the investigation of other biological mechanisms relevant to restenosis such as thrombus formation, endothelial cell function, and smooth muscle cell proliferation. Furthermore, the conventional stainless steel stent platform used in this model is similar to that used in clinical stents, and is amenable to surface-coating and drug-elution technologies, which would permit preclinical screening of potential antirestenotic stent-based coatings or drugs.
This model has some limitations. The procedure requires an advanced level of microsurgical skill. In our experience, 16% of stented vessels thrombosed despite aspirin therapy. The use of additional antiplatelet agents, such as clopidogrel, may further decrease the thrombosis rate. In terms of the response to injury, because of vessel size considerations, stents are deployed in the mouse aorta, which is a relatively elastic artery, and may respond differently to stenting compared with muscular coronary arteries. Furthermore, it is conceivable that the grafting procedure itself may contribute to the vascular injury response, for example by effects on the adventitia or vasa vasorum. We attempted to control for this possibility by grafting uninjured aortic segments, which did not develop histological changes compared with nongrafted aorta. Importantly, although we performed stenting in hypercholesterolemic atherosclerotic mice, we did not attempt to stent directly onto existing plaque. Rather, we investigated the biological response to stenting in a mouse known to have hypercholesterolemia, increased vascular inflammation, and high levels of oxidative stress. Future studies aimed at investigating the response to stenting plaque directly may provide important insight into the response to stenting in humans. Finally, additional studies are needed to validate the findings from this model with respect to established preclinical models (reviewed in4) and results from clinical trials.
In conclusion, we have established a new model of balloon angioplasty and stenting in mice which reproduces important features of human PCI and can address mechanisms of stent injury with high statistical and biological power. This model provides the opportunity to investigate molecular pathways and explore novel therapeutic targets for in-stent stenosis.
| Acknowledgments |
|---|
This work was funded by The Wellcome Trust and the British Heart Foundation.
Disclosures
None.
| Footnotes |
|---|
Original received July 7, 2006; final version accepted December 19, 2006.
| References |
|---|
|
|
|---|
Related Article:
This article has been cited by other articles:
![]() |
M. J. Post and J. Waltenberger Small Is Beautiful: A Miniature Stent Model Arterioscler. Thromb. Vasc. Biol., April 1, 2007; 27(4): 701 - 702. [Full Text] [PDF] |
||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
ATVB Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2007 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |